Biosensors

Stop recycling datasets: make your own biosensor data

ZP Team
Share

Your data, your contribution

The fastest way to stand out as a data scientist is to work on data nobody else has. Public datasets are invaluable for learning, but the most popular ones have been modelled thousands of times. Another small gain on the same benchmark is hard to publish and harder to get noticed for.

Generating your own data changes that. You control the experiment, you know exactly how every number was produced, and you can ask questions the existing datasets were never designed to answer. A new, well-documented dataset with a clear method is a contribution in its own right, before you have trained a single model.

Electrochemical biosensors are an unusually good place to start. They are small and fast: a measurement takes minutes, so you can build up hundreds of runs on your own desk.

Why biosensor data suits data scientists

A biosensor turns a chemical into an electrical signal, so every measurement is a time series with a physical story behind it. That combination is what makes it interesting to model:

  • Real noise: electronic noise, temperature effects and slow drift, not the tidy noise of a simulation.
  • Events you control: you add a known amount of analyte at a known time, so every change in the signal comes with ground truth.
  • Physics you can use: decay curves, saturating calibration curves and first-order responses give physics-informed models a real advantage over generic ones.
  • Change over time: reusable sensors age, so drift, calibration transfer and domain shift become questions you can study directly. One measurement already holds several problems: deciding when the sensor is ready, detecting events, forecasting where the signal will settle, calibrating with honest uncertainty, and tracking drift. Repeat it a hundred times and you have a dataset that is genuinely yours.

Two good places to start

We suggest beginning with one of two sensor families. They work on different principles, so they give you different kinds of data to model.

Enzyme-based sensor Ion-selective electrode (ISE)
Start with Glucose pH
What it measures A current, in microamps, as the analyte reacts at the electrode A voltage between two electrodes, set by the ion's activity
Typical signal A start-up decay, then a step up with each addition, levelling off at high concentration A stable potential that shifts with pH, roughly linear in pH
Modelling questions Settling time, event detection, forecasting the plateau, saturating calibration, drift with reuse Linear calibration and its slope, response time, hysteresis, drift over time

Glucose is the classic enzyme sensor: well understood, safe to handle and easy to prepare at known concentrations. pH is the classic ISE, and its near-linear response makes it a clean first calibration problem. Either one gives you a complete setup with the same electronics platform.

Starter set 1: glucose

Everything you need for a glucose dataset comes in four parts.

Item What it gives you Documentation
Glucose sensor Screen-printed sensor strips, 26.3 mm × 7.2 mm, with a platinum working electrode and silver/silver chloride reference and counter electrodes Datasheet
Biosensor Measurement Kit (choose the glucose option) The MicroPot G2 board, an adapter and a USB cable: plug in, start a measurement and stream the data to your computer User guide
Glucose calibration solution kit Eleven known concentrations, 0 to 20 mM in 2 mM steps, 10 ml of each: your ground truth
Sensor rinse solution For rinsing sensors between runs and before storage, so you can reuse them and build long series

The glucose sensors can typically be reused when operated under the recommended conditions, which is what makes drift and ageing studies possible. Store them at 2 to 8 °C, away from light, and use them within their three-month shelf life.

The board streams data over a standard USB serial connection, so you can read it straight into Python and a pandas DataFrame, or into Excel if you prefer.

Starter set 2: pH

The pH set uses the same electronics platform and rinse solution, with a different sensor and calibration solutions.

Item What it gives you Documentation
pH hyper value sensor Screen-printed sensor strips, 26.3 mm × 7.2 mm, with a carbon working electrode and silver/silver chloride reference and counter electrodes Datasheet
Biosensor Measurement Kit (choose the pH option) The same MicroPot G2 board, adapter and USB cable, configured for pH User guide
pH calibration solution kit Buffers at pH 4, 7 and 10, 30 ml of each
Sensor rinse solution The same rinse solution as the glucose set, for rinsing between runs and before storage

For pH the board measures the open-circuit potential: the voltage the sensor develops with no current flowing. In theory, an ideal pH electrode changes by about 59 mV per pH unit at 25 °C, so a first project almost writes itself: how close does a real sensor get, and how does its slope and offset change over time and temperature?

The pH sensors store at 2 to 15 °C, away from light, with a recommended shelf life of one year.

The board is easily removed from its adapter, so you can start with one sensor type and add the other later by swapping in the matching board.

From first run to publishable project

Start small, then let the dataset grow. A sensible path:

  1. One clean run. Record a single measurement and plot it. Learn what the start-up, the noise and a step change look like.
  2. A calibration series. Measure every calibration solution, several times each, with fresh and rinsed sensors. You now have repeated measurements with known ground truth.
  3. Reuse over days. Rinse, store and measure again. Each repeat adds to a time series of the sensor's own behaviour.
  4. Several sensors. Repeat on new strips from the same pack to see how much sensors differ from each other. Each stage opens questions worth writing up:
  • Faster answers: can a model predict the final reading from the first few seconds?
  • Honest uncertainty: how well calibrated are your error bars on held-out runs?
  • Drift and ageing: can you model how response changes with reuse, and correct for it?
  • Transfer: does a model trained on one sensor work on the next, and how little new data does it need?
  • Physics versus black box: when does a physics-informed model beat a neural network on small data? To make the work publishable, treat the data as a first-class result. Record every condition (sensor batch, temperature, timing, rinse steps), keep the raw files untouched, and share the data and code alongside the paper. A clearly documented dataset is something other researchers can build on and cite.

Beyond glucose and pH

Glucose and pH are starting points, not limits. Once you are comfortable with one sensor, the same workflow carries over to others:

  • More enzyme-based sensors: see our full range of enzymatic sensors.
  • More ion-selective electrodes: see our full range of ion-selective sensors. The Biosensor Measurement Kit is also available configured for lactate, potassium and calcium, so a second analyte can share the same adapter and cable. Measuring two analytes side by side opens up multivariate questions too, such as cross-sensitivity and sensor fusion.

Start generating

The next interesting dataset in your field may be one you record yourself. Pick a starter set, run your first measurement, and you will have data no one else has modelled.

Want to see what one curve can hold before you start? Join our free 30-minute webinar, One Curve, Five Machine Learning Problems, on Thursday 10 December. The same session runs twice, so register for whichever time suits you:

Explore Our Products

  • Glucose sensor

    Glucose sensor

    ZP Webstore

  • Product

    ZP Webstore

  • Biosensor Measurement KIt

    Biosensor Measurement KIt

    ZP Webstore

  • Product

    ZP Webstore

  • Glucose calibration solution kit

    Glucose calibration solution kit

    ZP Webstore

  • Sensor rinse solution

    Sensor rinse solution

    ZP Webstore

  • pH hyper value sensor

    pH hyper value sensor

    ZP Webstore

  • Product

    ZP Webstore

  • Biosensor Measurement KIt

    Biosensor Measurement KIt

    ZP Webstore

  • pH calibration solution kit

    pH calibration solution kit

    ZP Webstore

  • Enzymatic Sensors

    Enzymatic Sensors

    ZP Webstore

  • Ion Selective Sensors

    Ion Selective Sensors

    ZP Webstore